Ando AQ6331 Portable Optical Spectrum Analyzer , Long Wavelength Ando AQ6331

Brand Name : Ando

Model Number : AQ6331

Place of Origin : USA

MOQ : 1 set

Price : Negotiation

Payment Terms : T/T

Supply Ability : in stock

Product name : Yokogawa Optical Spectrum Analyzer

Condition : Pre-Owned

Functions : Tested, in Full Working Conditions

Contact Now

Ando AQ6331 Optical Spectrum Analyzer World Class Optical Performance Long Wavelength
Description of Ando AQ6331
  • The AQ6331 is a new portable optical spectrum analyzer (OSA) offering the advanced performance required for 50 GHz DWDM networktesting, in both C-band and L-band. The AQ6331 presents excellent wavelength resolution, accuracy and dynamic range which are equal to conventional bench-top OSAs for research and development applications. Thanks to its unique rugged design and portability, the AQ6331 is an ideal tool for field applications such as construction, inspection and maintenance work. It can also be used in production and quality control processes (e.g. component test and measurement). The AQ6331 is the only portable optical spectrum analyzer to bring scientific specs into field applications.

Feature:

● Compact and lightweight: Approx. 10 kg

● Wavelength accuracy: ±0.02 nm (1520-1580 nm) ±0.05 nm (1580-1620 nm)

● Wavelength resolution: 0.05 nm (min.)

● Dynamic range: 55 dB (peak ±0.4 nm) 40 dB (peak ±0.2 nm)

● Internal wavelength calibration With a built-in wavelength reference

● One-key-operation With a built-in user programming function

● Unique long-term measurement function To monitor DWDM system stability and performance

● Various built-in analysis functions

Specifications

Applicable fiber Single mode fiber (10/125 µm)
Applicable Connector FC-PC (Standard)
Wavelength range 1200 to 1700 nm
Wavelength accuracy ±0.02 nm (1520 to 1580 nm), < ±0.05 nm (1580 to 1620 nm), ±0.3 nm (1200 to 1700 nm)
Wavelength linearity ±0.01 nm (1520 to 1580 nm), < ±0.02 nm (1580 to 1620 nm)
Wavelength reproducibility ±0.005 nm (1 min.)
Wavelength resolution 0.05 nm (Resolution setting: 0.05 nm, 1520 to 1620 nm) 0.1 nm (Resolution setting: 0.1 nm, 1520 to 1620 nm) Resolution setting: 0.05, 0.1, 0.2, 0.5, 1.0 nm Resolution accuracy: < ±5% (Resolution setting: ≤ 0.2 nm)
Measurement level range -90 to +20 dBm (1200 to 1600 nm, sensitivity: HIGH3) -80 to +20 dBm (1600 to 1700 nm, sensitivity: HIGH3)
Level accuracy ±0.3 dB typ. (1550 nm, 1600 nm)
Polarization dependency ±0.05 dB (1550 nm, 1600 nm)
Level linearity ±0.05 dB (Input power: 0 to -50 dBm, sensitivity: HIGH 1 to 3
Level flatness ±0.1 dB (1520 to 1580 nm) ±0.2 dB (1520 to 1620 nm)
Level reproducibilit ±0.02 dB (1550 nm, 1600 nm)
Dynamic range 55 dB (1523 nm, peak ±0.4 nm, 0.05 nm resolution) 40 dB (1523 nm, peak ±0.2 nm, 0.05 nm resolution)
Return loss 30 dB typ. (Optical input, 1550 nm, 1600 nm)
Sweep time Approx. 0.5 sec. (Span: 50 nm, sensitivity: NORMAL HOLD, number of sampling: AUTO, average: 1
Functions
Measurement condition Auto-configuration, span, sensitivity (NORMAL HOLD/AUTO, HIGH 1/2/3), averageing, number of sampling (11 to 20001, AUTO), sweep between markers, 0-nm sweep, pulse light measurement
Trace display 3 individual Traces (Max/Min, rolling avarage, data calculation), frequency/wavelength axis
Data analysis WDM, EDFA, PMD, SMSR, search (Peak, Bottom), spectral width, notch-width, delta-marker, line marker
Others Program, long-term measurement, wavelength self-calibration
Memories FDD (3.5-inch 2HD), Internal memory (2MB)
Data output Built-in high-speed printer
Interfaces GP-IB, RS-232C, Keyboard (IBM compatible), Mouse (PS/2), Video (SVGA), Printer (Centronics), PCMCIA (1 x Type 3 or 2 x Type 2)
Display 8.4-inch color LCD (800 x 600 dots)
Power requirements AC100 to 120 V, AC200 to 240 V, 48 to 63 Hz, approx. 100 VA
Environmental conditions Operating temperature: 0 to 50°C Storage temperature: -20 to 60°C Humidity: 90% or less (no condensation)
Dimensions and mass Approx. 315(W) x 200(H) x 255(D) mm, approx. 10 kg

List of Options
RMS REMOTE MODEM SW
TC TRANSIT CASE

FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .

Ando AQ6331 Portable Optical Spectrum Analyzer , Long Wavelength Ando AQ6331Ando AQ6331 Portable Optical Spectrum Analyzer , Long Wavelength Ando AQ6331


Product Tags:

Long Wavelength Portable Optical Spectrum Analyzer

      

Ando AQ6331

      

Ando AQ6331 Portable Optical Spectrum Analyzer

      
Wholesale Ando AQ6331 Portable Optical Spectrum Analyzer , Long Wavelength Ando AQ6331 from china suppliers

Ando AQ6331 Portable Optical Spectrum Analyzer , Long Wavelength Ando AQ6331 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Meigaolan Electronic Instrument Co. Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)